5 Results for the search " import":
Author: e.malaval
Type: Model
Downloaded: 21 times
Date: 2022-01-19
Extract data from input file
Description:
If you attach the script to a device, by putting the path of "script.dwj" in the attribute "Script.open.Dev", a window opens when you double-click on the device.
... see more>
This wndow allows to copy the content of a file in the "Modeldata" attribute.
Tag(s): input file, script, import
Author: n.sene
Type: Publication
Date: 2015-04-01
AN ADVANCED INTERFACE BETWEEN THE LIOV CODE AND THE EMTP-RV
Description:
Accurate evaluation of the response of overhead distribution lines to lightning electromagnetic pulse (LEMP) represents an important aspects in insulation coordination of distribution network. The imp... see morerovements of the accuracy of such an analysis call for the extension of the field-to-transmission line coupling models from single straight lines to multi-conductor/branched and complex systems. This paper deals with the description of a new interface between the LIOV (Lightning Induced OverVoltage) code and the EMTP-RV software. In particular, the paper illustrates the treatment of the boundary conditions – on which the link with the Augmented Nodal Analysis Technique adopted by the EMTP-RV is based – together with the main aspects related to the numerical integration of the Agrawal and al. LEMP-to-transmission line coupling model adopted in the LIOV code.
The proposed interface aims at improving the simulation capabilities of the previous version of the LIOV-EMTP, namely this new version completely removes the disadvantage of the time-delay associated to the use of a short Bergeron’s line needed to link the LIOV code with the EMTP. Additionally, this new version of the LIOV-EMTP code takes advantages of the Augmented Nodal Analysis Technique implementation in EMTP-RV. Comparison with experimental results is also presented in order to verify the accuracy of the proposed interface.
Authors: A. Borghetti, F. Napolitano, C.A. Nucci, M. Paolone, J. Masheredjian, F. Rachidi
29th Conference on Lightning Protection 23rd – 26th June 2008 Uppsala, Sweden
Author: n.sene
Type: Publication
Date: 2015-04-01
Transient recovery voltages in vacuum circuit breakers generated by the early-interruption of the inrush current of large motors
Description:
The switching of medium voltage electrical motors is typically realized by means of vacuum circuit breakers (VCBs) essentially in view of their elevated number of switching cycles. As known, switching... see more of VCBs generates important transient recovery voltages (TRVs)
that need to be properly evaluated in both VCB sizing and in the power system insulation coordination. As large medium voltage electrical motors are installed into plants typically controlled by means of Supervisory Control And Data Acquisition (SCADA) systems,
maneuvers that involve the motor inrush followed by its sudden de-energization (due, in general, to the intervention of an automatic diagnostic function), resulting into important TRVs, are not unusual. The paper aims at investigating the TRVs due to this specific type of
VCB switching by means of a model implemented in the EMTP-RV simulation environment. By making reference to a real plant, the validation of the implemented models is obtained by comparing the simulation results with some experimental transients provided by the plant data fault recorder. The paper finally discusses the adequacy of different countermeasures by analyzing their effectiveness for the TRVs limitation.
Authors: A. Borghetti, F. Napolitano, C.A. Nucci, M. Paolone, M. Sultan, N. Tripaldi
CIGRE - International Symposium “Assessing and Improving Power System Security, Reliability and Performance in Light of Changing Energy Sources” Recife, Pernambuco, Brazil, April 3-6, 2011
Topic 3 – System technical performance
Subtopic 3.5 – Switching and lightning transient on power systems. Impact on performance and measurements
Tag(s): Transient recovery voltages, vacuum circuit breakers, motor inrush currents, EMTP simulations
Author: e.rutovic
Type: Example
Downloaded: 587 times
Date: 2013-02-20
EMTP-RV to Matlab
Description:
This script imports the EMTP-RV output data inside the Matlab Workspace.
The files with the extension ".mda" and ".m" must be placed inside the Matlab current ... see morefolder.
You should run "main.m" .
Author: AdminEMTP-RV
Type: Model
Downloaded: 320 times
Date: 2012-06-18
Ferro_hyst_Zno
Description:
Simple ferroresonance case. In this case the switching of a part of the network comprised of a cable connected to a no-load transformer is carried out. A pole of the breaker fails to open and an impor... see moretant and stable ferroresonance phenomena appears.
The ferroresonance problem, whether in a general circuit or in a power-system circuit, is usually tackled in one of two ways : circuit configuration (i.e series and/or parallel) or nonlinearities (i.e saturation and hysteresis of transformers). A fundamental factor to the occurence of ferroresonance is the nonlinear magnetizing characteristic of the transformer and the capacitive coupling.
In this case a 250 kVA, 20/0.4 kV transformer is used. This transformer is represented by the hysteresis transformer model. The hysteresis element has been used as the magnetization branch of the one-phase transformer model. A 200 m cable is used for the study. This cable is modelled by a PI-section. The short circuit power of the source is about 150 MVA.
In order to reduce overvoltages caused by ferroresonance, surge arresters are installed. Two questions have emerged : will the arresters mitigate ferroresonance, and will they fail during ferroresonance ? Simulations in different transient regimes can be carried out in order to determine the maximal current, overvoltages (voltage at the end of the cable for instance), energy absorbed by the arresters
Tag(s): Protection