Description:
The papers addresses the problem of locating surge protective devices in a medium voltage distribution network by means of an accurate computer model for the calculation of lightning induced overvolta... see moreges and a Monte Carlo statistical procedure. The indirect lightning performance of small network cells of different configuration are evaluated and used as a benchmark for the validation of the surge arrester locations provided by a genetic algorithm procedure. The obtained results appear useful for the lightning protection design of networks
with complex topology.
Authors: Alberto Borghetti, Fabio Napolitano, Carlo Alberto Nucci, Fabio Tossani, Gilnei J. G. Dos Santos, Donorvan R. Fagundes, Gustavo P. Lopes, Manuel L. B. Martinez
2014 International Conference on Lightning Protection (ICLP), Shanghai, China
Description:
For the accurate statistical assessment of the lightning performance of distribution lines one needs to
take into account the presence of protection devices such as surge arresters and shielding ... see morewire/neutral
groundings. Indeed, the presence of those devices can significantly modify the indirect lightning
response of the overhead line and, therefore, the relevant lightning performance.
In particular, this paper aims at investigating the impact of the presence of surge arresters on the
indirect lightning performance of overhead distribution lines having realistic configuration.
Specifically, reference is made to typical Italian distribution lines. The investigation is performed with
the help of a statistical procedure developed by the authors – based on the Monte Carlo method and of
the use of an accurate modelling/calculation tool for the induced surges – that has been recently
compared with one proposed in the IEEE 1410 Std for the same purpose, and shown to be more
complete and suitable for the problem of interest. The paper also aims at investigating the influence of
the presence of surge arresters on the indirect lightning surges transferred through power transformers.
Such an additional investigation is performed by means of a suitable high-frequency power
transformer mode integrated with the lightning-induced computation tool.
Authors: A. Borghetti, F. Napolitano, C.A. Nucci and M. Paolone - University of Bologna, Italy
CIGRE – Colloquium Cavtat - Application of Line Surge Arresters in Power Distribution and Transmission Systems
Description:
The paper deals with the analysis of the possible correlation between cloud-to-ground lightning discharges and relay operations inferred by using the experimental data obtained means of a measurement ... see moreset-up, installed on an Italian MV distribution network, and a statistical procedure based on the coordinated use of the Italian Lightning Location System (LLS) CESI-SIRF, the monitoring systems of protection manoeuvres and an advanced simulation tool for the calculation of lightning induced overvoltages. The procedure takes into account the uncertainties related to the estimation of lightning stroke location and current amplitude provided by the LLS. The experimental set-up, composed by a distributed monitoring system, is able to measure a-periodic voltage transients characterized by a frequency content up to 4 MHz. Three of these units have been installed in the feeder of a three-phase overhead distribution network with a total length of 21 km. The same feeder is protected with overcurrent and zero-sequence relays whose operations are recorded by a monitoring system with a 10-ms sampling time. The data collected during one year of operation of the experimental set-up have been analyzed together with the data collected by the LLS for a 144 km2 area covering the equipped feeder and its surrounding area, in order to account for all direct and indirect lightning events that may have caused a relay intervention. The data have been also used to test the calculation model. The paper eventually reports the results of the correlation analysis carried out using the mentioned procedure, which is used to evaluate the probability that a specific event, detected by the LLS and time-correlated to relay operation, may have been the cause of a flashover in the network.
Authors: A. Borghetti, F. Napolitano, C.A. Nucci, M. Paolone, M. Bernardi, F. Rachidi, K. Yamabuki
Description:
This paper deals with the calculation of lightning induced overvoltages on medium-voltage (MV) and low-voltage (LV) distribution networks taking into account the presence of MV–LV distribution trans... see moreformers and, in particular, the surge transfer through them. The influence of the high-frequency model adopted for the representation of the power transformer on the calculation results is analyzed, with regards to two different models, both identified and validated by means of laboratory measurements: namely, a simple π of capacitances, and the more complex one introduced by Morched, Marti, and Ottevangers in 1993. Accurate simulation results provide information on the adequacy of both models for the calculations of interest. Additional results, useful to evaluate the expected level of power quality and the benefits achievable by a proper installation of protection devices, are presented making reference to a realistic and complex configuration of an overhead distribution system
Authors: Alberto Borghetti, Atef Morched, Fabio Napolitano, Carlo Alberto Nucci, Mario Paolone,
IEEE TRANSACTIONS ON POWER DELIVERY, VOL. 24, NO. 1, JANUARY 2009
Description:
The aim of the paper is to analyze overvoltages in overhead distribution lines induced by nearby lightning return stroke currents taking into account also the conductive coupling between the lightning... see more current injected into the soil and the line’s grounding system. Experimental results obtained in 2003 at the International Center for Lightning Research and Testing (ICLRT) in Florida have shown that significant currents were coupled with an overhead experimental line through its grounding system by nearby rocket-triggered lightning.
The paper first proposes a conductive coupling model between the lightning current injected into the soil and the nearby line grounding system, then presents the incorporation of such a model into the LIOV-EMTP computer code. The paper finally presents an experimental validation of the proposed models by making reference to results obtained during the above-mentioned triggered-lightning campaign.
Authors: F. Napolitano, M. Paolone, A. Borghetti, C.A. Nucci, F. Rachidi, V.A. Rakov, J. Schoene and M. A. Uman
Description:
A joint research project between AES Sul, the Federal University of Itajubá and the University of Bologna aims at defining the required protections against lightning-originated overvoltages in a reso... see morenant grounded distribution system in order to achieve the adequate lightning performance level with minimum cost. The paper aims at illustrating the effectiveness of the presence of a surge arrester or spark gap and their protective zone by means of simulations obtained with a computer code for the calculation of lightning induced voltages that takes also into account the steady-state voltage. The results of a statistical analysis for a single multiconductor line are eventually presented and discussed.
Authors: A. Borghetti, F. Napolitano, C.A. Nucci, M.L.B. Martinez, G.P. Lopes, J.I.L. Uchoa
2012 International Conference on Lightning Protection (ICLP), Vienna, Austria
Description:
The assessment of the lightning performance of a compact configuration of MV overhead lines that is expected to be adopted in the near future by an electricity distribution company in a Brazilian regi... see moreon characterized by high keraunic levels is presented. The compact configuration is characterized by the presence of an unenergized wire that has the main function to sustain the spacers of the phase conductors. As the wire could be periodically grounded, the paper analyses its effectiveness in reducing the overvoltages due to indirect lightning. The results are compared with those relevant to a conventional configuration of MV overhead lines now adopted by the same distribution company. The effects of the presence of surge arresters along the line are also analysed.
Authors: F. Napolitano, A. Borghetti, D. Messori, C.A. Nucci, M.L.B. Martinez, G.P. Lopes, J.I.L. Uchoa
Description:
Authors:
A. Xémard, P. Baraton, B. Bressac, N. Qako, J. Mahseredjian, G. Simard, J. Ribeiro, R. Tarafi, A. Zeddam.
Abstract:
LIPS (Lightning Impact on Power Systems) is a toolbo... see morex based on EMTP (DCG version) and devoted to the calculation of the failure rate of apparatus due to lightning. This software covers direct and induced lightning. It has been developed in a partnership project between France Telecom, Hydro-Québec and électricité de France. The induced lightning nearby the electrical system. It is based on the following computational steps:
1) For each overhead line and underground cable of the electrical system, two equivalent current sources are calculated in the frequency domain, representing the illumination of the conductors by external electrical field due to lightning. These sources are evaluated in the frequency domain, taking into account the variation of the parameters of lines and cables with frequency. The conductivity of the ground is taken as finite. The modal theory is applied in the case of multi-conductor cable or line.
2) The equivalent sources are converted into time-domain and then included in an EMTP representation of the system allowing a time-domain transient computation. this approach and follow by comparisons between induced overvoltages calculated by LIPS and results from the literature.