3 Results for the search " stability":
Dynamic Exponential Load
Description:
This device is an implementation of the three-phase exponential load model. The load active power and reactive power vary as function of its voltage amplitude and frequency. This device is implemented... see more as described in [1]. It allows to perform classical and sophisticated dynamic-stability studies in EMTP. This device can be used in the load flow and time-domain simulations.
During the load initialization, the initial active power and initial reactive power are used to find the load-flow. The load voltage magnitude and phase with update from the load flow results automatically.
[1] "Load representation for dynamic performance analysis (of power systems)," IEEE Transactions on Power Systems, vol. 8, no. 2, pp. 472-482, May 1993.
Tag(s): dynamic, load, frequency, exponential, stability,
Modular Multilevel Matrix Converter for Low-Frequency AC Transmission – modeling and Simulation in EMTP
Description:
Authors: Rafael Castillo-Sierra and Giri Venkataramanan
The transmission of power with AC faces limitations both to the stable operation of the electrical system and to the physical properties of... see more the transmission lines. Therefore, alternatives are being sought to mitigate these problems without the need to build new lines or replace existing ones with new, more powerful ones. In this context, a proven method makes it possible to overcome these problems by reducing the frequency at which power is transmitted. This method is known as Low Frequency AC Transmission (LFAC). In this sense, the model presented in this Research Contribution Prize Program EMTP® 2021 shows the implementation of a low-frequency transmission line in a small power system. The model presented shows a new block in EMTP of the AC/AC converter used, the Modular Multilevel Matrix Converter (MMMC) and the controls necessary for its operation. Time domain studies show that the technology is feasible and has the potential to improve the controllability and stability of transmission systems.
Tag(s): AC-AC power conversion, Electromagnetic Transient Studies in EMTP, Low frequency AC transmission, Modular Multilevel Matrix Converter
Extra control of machines - IEEE AVR
Description:
The proposed AVR sub-circuit models consist of a few IEEE 421 standard exciter[1] and Power Systems Stabilizer and governor. Don't forget to click the require observed signals in the SM devi... see morece, see Observe and Mechanical Tabs (vd, vq, if, Pmss, Efss, Omega_1, etc.) In this file, many duos and trios combinations of:
Exciter:
- IEEEX1 (dc1),
- IEEEX2,
- IEEEX4,
- IEEET5,
- EXST1,
- EXST1A,
Stabilizer:
- PSS1A,
- PSS2B,
- PSS4B,
- Q type II (var control)
Governor:
- IEEEG0,
- IEEEG1,
- IEEEG3,
- DEGOV1
- GAST,
- TGOV1,
- TGOV5[1]
IEEE Std 421.5, Recommended Practice for Excitation System Models For Power System Stability Studies, 2005
Tag(s): Components