Short-Term Scheduling of Active Distribution Systems
Description:
The latest distribution management systems tend to incorporate optimization functions for the short-term scheduling of the various energy and control resources available in the network (e.g., embedded... see more generators, reactive power compensators and transformers equipped with on-load tap changers). The short-term scheduling procedure adopted in the paper is composed by two stages: a day-ahead scheduler for the optimization of distributed resources production during the following day, an intra-day scheduler that every 15 minutes adjusts the scheduling in order to take into account the operation requirements and constraints of the distribution network. The intra-day scheduler solves a non-linear multi-objective optimization problem by iteratively applying a mixed-integer linear programming (MILP) algorithm. The linearization of the optimization function and the constraints is achieved by the use of sensitivity coefficients obtained from the results of a three phase power flow calculation. The paper shows the application of the proposed approach to a medium-voltage 120 buses network with 10 dispatchable generators and 2 transformers equipped with on-load tap changers.
Authors: A. Borghetti, M. Bosetti, S. Grillo, M. Paolone, F. Silvestro
IEEE Bucharest Power Tech Conference, June 28th - July 2nd, Bucharest, Romania
Tag(s): Distributed generation, operation of distribution networks, MILP.
Author: n.sene
Type: Publication
Date: 2015-04-02
SITL and HLA Co-simulation Platforms: Tools for Analysis of the Integrated ICT and Electric Power System
Description:
Due to the necessity of developing analysis tools in the integrated ICT and power system domain, this paper describes and compares the architecture and configuration of two different ITC-power system ... see moreco-simulation approaches called SITL (System in the Loop) and HLA (High Level Architecture) Co-simulation platforms. Both platforms make use of the communication network simulator OPNET (Optimum Network Performance). As indicated by the names, the former operates in real time, in order to perform SITL simulations, whilst the latter is based on the HLA interface between OPNET and the power network simulation environment EMTP-rv (Electromagnetic Transient Program). We provide several details on their implementation and present their features by means of the results obtained for two test cases. The paper aims at clarifying the type of analysis that can be effectively carried out by using the two different platforms.
Authors: Riccardo Bottura, Davood Babazadeh, Kun Zhu, Alberto Borghetti, Lars Nordström, Carlo Alberto Nucci
EuroCon 2013 • 1-4 July 2013 • Zagreb, Croatia
Tag(s): Co-simulation, OPNET, EMTP, High level architecture, System in the loop, Smart grid, OPAL-RT.
Author: n.sene
Type: Publication
Date: 2015-04-02
Simulation of the Volt/Var Control in Distribution Feeders by Means of a Networked Multiagent System
Description:
The adoption of networked multiagent systems (MAS) has been recently proposed for the solution of the volt/var control (VVC) problem in distribution feeders. However, constraints and limitations due t... see moreo the communication network, to the dynamic behavior of power system components and regulators, as well as to the measurement uncertainties of the adopted sensors need to be specifically analyzed for the design of the MAS. For this purpose, a cosimulation platform has been built by the integration of two simulation tools:
1) the electromagnetic transient program EMTP-rv; and 2) the communication network simulator Riverbed-OPNET Modeler. This paper presents the modeling and simulation of an asynchronous leaderless MAS-based approach that coordinates the reactive power outputs of a set of power compensators equipped with phasor measurement units via a shared band-limited packet-switched digital communication network. The effects of communication network latency and packet loss on the VVC performances are analyzed for two unbalanced IEEE Test feeders equipped with on-load tap changer transformers. The paper compares the results obtained by using a transmission control protocol (TCP) and a user datagram protocol (UDP), for different levels of background traffic (BT) and different packet discard ratios (PDRs) in the communication links.
Authors: Riccardo Bottura, Student Member, IEEE, and Alberto Borghetti, Senior Member, IEEE
IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, VOL. 10, NO. 4, NOVEMBER 2014
Tag(s): Cosimulation, medium voltage distribution feeders, multiagent systems (MAS), networked control systems (NCS), phasor measurement unit (PMU), volt/var control (VVC).
Author: n.sene
Type: Publication
Date: 2015-04-01
DISPERSED ENERGY RESOURCES SCHEDULING FOR THE INTENTIONAL ISLANDING OPERATION OF DISTRIBUTION SYSTEMS
Description:
The paper presents an algorithm for the automatic optimal scheduling of dispersed energy resources (DERs) and of under-load tap changers (ULTCs) position. The aim of the scheduling problem consists in... see more the minimization of the voltage deviations with respect the rated value, of the DERs production deviation with respect the maximum efficiency point, and of the network losses.
The system incorporates also a procedure to facilitate the intentional islanding maneuver of the distribution network. The adopted approach is based on iterative solution of linear-constrained multi-objective optimization problems. The nonlinear power flow relationships are linearized by means of the calculation of sensitivity coefficients to small variations of the control variables (namely, controllable DERs power outputs and ULTCs positions). The algorithm is implemented in Matlab environment to exploit different solvers and suitably interfaced with EMTP-RV for three-phase power flow detailed calculations. In particular, two optimization solvers are adopted: the least square method and the goal attainment approach. The relevant results are compared using the IEEE 34-node distribution feeder as test case.
Authors: A. Borghetti, C.A. Nucci, M. Paolone, M. Bosetti