See Simulation of the Volt/Var Control in Distribution Feeders by Means of a Networked Multiagent System
Author: n.sene
Type: Publication
Date: 2015-04-02
Rating:
* 0 vote(s)

Simulation of the Volt/Var Control in Distribution Feeders by Means of a Networked Multiagent System

Description:
The adoption of networked multiagent systems (MAS) has been recently proposed for the solution of the volt/var control (VVC) problem in distribution feeders. However, constraints and limitations due t... see more
Tag(s): Cosimulation, medium voltage distribution feeders, multiagent systems (MAS), networked control systems (NCS), phasor measurement unit (PMU), volt/var control (VVC).

See On the Mitigation Effect of Surge Arresters on the Lightning Performance of Overhead Distribution Lines
Author: n.sene
Type: Publication
Date: 2015-04-01
Rating:
* 0 vote(s)

On the Mitigation Effect of Surge Arresters on the Lightning Performance of Overhead Distribution Lines

Description:
For the accurate statistical assessment of the lightning performance of distribution lines one needs to
take into account the presence of protection devices such as surge arresters and shielding ... see more
Tag(s): Lightning statistics, induced overvoltages, lightning performance of distribution lines, surge arresters, shielding wires groundings, Monte Carlo method.

See Lightning-Induced Overvoltages Transferred Through Distribution Power Transformers
Author: n.sene
Type: Publication
Date: 2015-04-01
Rating:
* 0 vote(s)

Lightning-Induced Overvoltages Transferred Through Distribution Power Transformers

Description:
This paper deals with the calculation of lightning induced overvoltages on medium-voltage (MV) and low-voltage (LV) distribution networks taking into account the presence of MV–LV distribution trans... see more
Tag(s): Lightning, distribution transformers, overvolatges

See JavaScript Examples
Author: e.rutovic
Type: Example
Downloaded: 921 times
Date: 2013-02-20
Rating:
* 7 vote(s)

JavaScript Examples

Description:
Some simple EMTP-RV scripts :
- Parameters sweep
- Change the simulation options
- Run simulation
- Change the fault location
- Change the transformer remanent flux
- Cha... see more
Tag(s): Script, Javascript

See Ferro_hyst_Zno
Author: AdminEMTP-RV
Type: Model
Downloaded: 298 times
Date: 2012-06-18
Rating:
* 0 vote(s)

Ferro_hyst_Zno

Description:
Simple ferroresonance case. In this case the switching of a part of the network comprised of a cable connected to a no-load transformer is carried out. A pole of the breaker fails to open and an impor... see more
Tag(s): Protection