34 Results for the search "line":
Author: n.sene
Type: Publication
Date: 2015-04-01
VOLTAGE TRANSIENTS IN A DISTRIBUTION NETWORK CORRELATED WITH EVENTS IDENTIFIED BY A LIGHTNING LOCATION SYSTEM
Description:
Monitoring units for the measurement of high frequency voltage transients have been in operation at three different busses of an Italian medium voltage (MV) distribution feeder, mainly composed by ove... see morerhead lines, in March 2007 – August 2008. The feeder is located in a region characterized by a high ground flash density value (4 flashes/km2/yr); many of the recorded voltage transients may be correlated with the lightning events detected for the same region by the Lightning Location System (LLS) CESISIRF. The paper presents some experimental results obtained using the monitoring units and their comparison with computer results obtained using a LIOV-EMTP model of the considered MV feeder. A procedure aimed at achieving the best fit between measurements and calculations, which takes into account the uncertainties associated with LLS data, is also presented.
Authors:A. Borghetti, F. Napolitano, C.A. Nucci, M. Paolone, M. Bernardi, W. Schulz
X International Symposium on Lightning Protection, 9th-13th November, 2009 – Curitiba, Brazil
Tag(s): Lightning, distribution network, LIOV, EMTP
Author: n.sene
Type: Publication
Date: 2015-04-01
Interaction Between Grounding Systems and Nearby Lightning for the Calculation of Overvoltages in Overhead Distribution Lines
Description:
The aim of the paper is to analyze overvoltages in overhead distribution lines induced by nearby lightning return stroke currents taking into account also the conductive coupling between the lightning... see more current injected into the soil and the line’s grounding system. Experimental results obtained in 2003 at the International Center for Lightning Research and Testing (ICLRT) in Florida have shown that significant currents were coupled with an overhead experimental line through its grounding system by nearby rocket-triggered lightning.
The paper first proposes a conductive coupling model between the lightning current injected into the soil and the nearby line grounding system, then presents the incorporation of such a model into the LIOV-EMTP computer code. The paper finally presents an experimental validation of the proposed models by making reference to results obtained during the above-mentioned triggered-lightning campaign.
Authors: F. Napolitano, M. Paolone, A. Borghetti, C.A. Nucci, F. Rachidi, V.A. Rakov, J. Schoene and M. A. Uman
Tag(s): lightning induced overvoltages, grounding systems, overhead distribution lines, lightning protection.
Author: n.sene
Type: Publication
Date: 2015-04-01
Protection Systems Against Lightning-Originated Overvoltages in Resonant Grounded Power Distribution Systems
Description:
A joint research project between AES Sul, the Federal University of Itajubá and the University of Bologna aims at defining the required protections against lightning-originated overvoltages in a reso... see morenant grounded distribution system in order to achieve the adequate lightning performance level with minimum cost. The paper aims at illustrating the effectiveness of the presence of a surge arrester or spark gap and their protective zone by means of simulations obtained with a computer code for the calculation of lightning induced voltages that takes also into account the steady-state voltage. The results of a statistical analysis for a single multiconductor line are eventually presented and discussed.
Authors: A. Borghetti, F. Napolitano, C.A. Nucci, M.L.B. Martinez, G.P. Lopes, J.I.L. Uchoa
2012 International Conference on Lightning Protection (ICLP), Vienna, Austria
Tag(s): Lightning protection, power distribution networks, induced overvoltages.
Author: n.sene
Type: Publication
Date: 2015-04-01
Assessment of the Lightning Performance of Compact Overhead Distribution Lines
Description:
The assessment of the lightning performance of a compact configuration of MV overhead lines that is expected to be adopted in the near future by an electricity distribution company in a Brazilian regi... see moreon characterized by high keraunic levels is presented. The compact configuration is characterized by the presence of an unenergized wire that has the main function to sustain the spacers of the phase conductors. As the wire could be periodically grounded, the paper analyses its effectiveness in reducing the overvoltages due to indirect lightning. The results are compared with those relevant to a conventional configuration of MV overhead lines now adopted by the same distribution company. The effects of the presence of surge arresters along the line are also analysed.
Authors: F. Napolitano, A. Borghetti, D. Messori, C.A. Nucci, M.L.B. Martinez, G.P. Lopes, J.I.L. Uchoa
CIGRE SC C4 2012 Hakodate Colloquium
Tag(s): Lightning protection, Overhead distribution lines, Induced overvoltages, Electromagnetic transients.
Author: gerinlajoie.luc
Type: Model
Downloaded: 123 times
Date: 2012-11-23
Pseudo Aleatory Volt/Ampere source
Description:
Pseudo Aleatory Volt/Ampere source single and three phases devices. Build with Base Line Wander generator. Useful for Spectrum Analysis
nota bene: ts must be a multiple of dt.
Tag(s): Source