Dear Ladies and Gentlemen,
this is my first forum contribution so please excuse me, if I should post anything wrong.
I have the following set up for my recent project:
3 cables with 2 conductors each (layed straight)
and another cable with 2 conductors which is continously transposed (twisted (like a twisted two-pair)).
Question:
They are included in the "CP line/cable m-phase" block. My problem now is, that there is only a global option for: "Continously Transposed" but only 2 conductors in one cable are transposed/twisted. What would be the best way to model a system where multiple cables influence each other but only some of them are twisted?
Thank you very much in advance.
René
Hi René,I suggest to model
Hi René,
I suggest to model the cable using a "Real Transformation Matrix" (No transposition) and to divide the cable in several sections. You can then connect all the sectiosn in series and transpose only the two conductors concerned.
I hope this helps.
Emmanuel.