Protection Toolbox

The next level for Protection studies has arrived!
 

 

This toolbox opens new doors for the simulation and analysis of protection systems. Both steady-state and time-domain simulation options are available. All relay, fuse and thermal element models are solved in time-domain with nonlinear functions, such as CT, VT and CVT magnetization. This new implementation for EMTP® allows to achieve highest levels of accuracy for protection coordination and analysis of performance with highly accurate power system models.

The power system may include many details ranging from power electronics models, HVDC transmission models and wind generation combined with traditional generation and transmission. There are no limitations! The relays can capture transients, harmonics, and various effects from power electronics based device controls.

Setting protection systems for renewable energies is finally made easy with the new EMTP® Protection Toolbox. The user can study any power system including inverter based devices for coordinating power-swing detection, distance protections, the interruption of currents by current-limiting fuses or determination of transformer differential protection settings.

1 hour free technical call

Get an introduction to the  
Protection Toolbox  
with EMTP®

Schedule your call

CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.

EMTP® design set up for protection studies

EMTP® design set up for protection studies
 
 
 
 

1. Distance protection

  • Four Zones of Phase and Ground Distance Protection
  • Polarized Mho, Lens or quadrilateral characteristics
  • Voltage polarization options from the main relay manufacturers
  • Zones and impedance locus drawing in R-X plan 
  • Overcurrent reactance and directional supervisors, Load encroachment supervisor, Fault-Identification Selection (FIDS)
  • Zone and impedance locus drawing in R-X graphs

Distance protection

Distance protection

 


 

2. Power-swing detection / Out-of-step tripping

  • 2 or 3-step detection
  • Mho, Lens or quadrilateral characteristics with Blinders
  • Continuous impedance calculation
  • Based on Manufacturers algorithms

Power Swing detection

Power Swing detection

 


 

3. Differential protection

  • 2 or 3-winding transformer with tap changers
  • Phase and ground differential
  • Harmonics inhibit and restraint options
  • External fault detection based on manufacturers algorithms
  • Transmission Line Differential Protection
  • Alpha plane visualization and protection

Differential current during transformer inrushDifferential current during transformer inrush

Alpha plane visualizationAlpha plane visualization

 


 

4. Overcurrent protection

  • More than 60 tripping and reset time curves
  • Phase, ground, negative sequence, zero-sequence protection
  • Possibility to add user-defined curves
  • Voltage restraint
  • Positive-sequence restraint options
  • 2 levels for each protection

Overcurrent protection - Time Current coordination

Overcurrent protection - Time Current coordination

 

 


 

5. Loss-of-field

  • Two Mho zones
  • Typical setting calculator

 

Graph of Loss of field

 Loss of field


 

6. Fuse

  • Current-limiting and expulsion fuses
  • Peak Let-Thru characteristic
  • Possibility to add user-defined curves
  • Melting curve, Pre-arc and Clearance energies

The protection toolbox has 3 levels:

• Level 1: Full access and modification license
• Level 2: Access and visualization only license
• Level 3: No access to subcircuit contents

 

Effect of current-limiting fuse

Effect of current-limiting fuse


 

 
7. Undervoltage / Overvoltage protection
 
8. Under frequency / Over frequency / Rate of change of Frequency protection