Exchange Platform

To download or upload a file, please login

page 6 of 11

55 Results for the search "Model":

See Micro-Grid library

Author: h.gras
Type: Library
Downloaded: 1475 times
Date: 2016-03-16

Rating:
* 7 vote(s)

Micro-Grid library

Description:
Convenient library to study Micro-grid. Contain:
- a 3-phase inverted with dq0 control (PQ, PV, VF, droop)
- a battery model (Ideal, i-Ion, Lead-Acid, NiMH, NiCD)
- a PV park
- Win... see more


Tag(s): Micro, grid, smart, inverter, dq0, battery, BMS, VSC, filter, delay, trigger, Wind, PV, photovoltaic, park, power, electronics

See Content of the webinar studies from A to Z on TRV

Author: h.gras
Type: Example
Downloaded: 734 times
Date: 2015-06-16

Rating:
* 3 vote(s)

Content of the webinar studies from A to Z on TRV

Description:
Designs built or presented during the webinar of the series Studies from A to Z on Transient Recovery Voltage
Models built:
- Rating TRV envelop (IEC 62271-100 / C37.010 - 2011)
- CP / ... see more


Tag(s): TRV, Transient recovery voltage, short-line fault, terminal fault, substation, 62271, 37.011, lines, switching, thevenin

See Content of the webinar studies from A to Z on lightning strokes

Author: h.gras
Type: Example
Downloaded: 885 times
Date: 2015-06-16

Rating:
* 1 vote(s)

Content of the webinar studies from A to Z on lightning strokes

Description:
Designs built or presented during the webinar of the series Studies from A to Z on Lightning stroke analysis.
Models built:
- Metal Oxide surge arrester (IEEE working group 3.4.11)
- To... see more


Tag(s): Lightning, stroke, fast-front transient, tower, arrester, cigre, line, substation, parametric, corona, air-gap, leader

See Selection of MV/LV Transformers to be Protected by Surge Arresters against Indirect Lightning Overvoltages

Author: n.sene
Type: Publication
Date: 2015-04-02

Rating:
* 2 vote(s)

Selection of MV/LV Transformers to be Protected by Surge Arresters against Indirect Lightning Overvoltages

Description:
The papers addresses the problem of locating surge protective devices in a medium voltage distribution network by means of an accurate computer model for the calculation of lightning induced overvolta... see more


Tag(s): distribution network; surge arresters; lightning protection.

See lCT -power Co-simulation Platform for the Analysis of Communication-based Volt/Var Optimization in Distribution Feeders

Author: n.sene
Type: Publication
Date: 2015-04-02

Rating:
* 0 vote(s)

lCT -power Co-simulation Platform for the Analysis of Communication-based Volt/Var Optimization in Distribution Feeders

Description:
The paper presents an ICT and power co-simulation platform for the analysis of the voltlvar control and relevant optimization in medium voltage distribution feeders, achieved by means of a system of d... see more


Tag(s): Co-simulation, Networked Control Systems, Power distribution feeders, Voltlvar optimization.

Most Downloaded

Top Model Exchanges

Top Examples

X