128 items shared, ordered by upload date:
JavaScript Examples
Description:
Some simple EMTP-RV scripts :
- Parameters sweep
- Change the simulation options
- Run simulation
- Change the fault location
- Change the transformer remanent flux
- Cha... see morenge the switching Times
Tag(s): Script, Javascript
EMTP-RV to Matlab
Description:
This script imports the EMTP-RV output data inside the Matlab Workspace.
The files with the extension ".mda" and ".m" must be placed inside the Matlab current ... see morefolder.
You should run "main.m" .
Extra control of machines - IEEE AVR
Description:
The proposed AVR sub-circuit models consist of a few IEEE 421 standard exciter[1] and Power Systems Stabilizer and governor. Don't forget to click the require observed signals in the SM devi... see morece, see Observe and Mechanical Tabs (vd, vq, if, Pmss, Efss, Omega_1, etc.) In this file, many duos and trios combinations of:
Exciter:
- IEEEX1 (dc1),
- IEEEX2,
- IEEEX4,
- IEEET5,
- EXST1,
- EXST1A,
Stabilizer:
- PSS1A,
- PSS2B,
- PSS4B,
- Q type II (var control)
Governor:
- IEEEG0,
- IEEEG1,
- IEEEG3,
- DEGOV1
- GAST,
- TGOV1,
- TGOV5[1]
IEEE Std 421.5, Recommended Practice for Excitation System Models For Power System Stability Studies, 2005
Tag(s): Components
Extra control functions
Description:
Extra control functions, 17 components: Dead band, Friction, QuantizerLess than (for T1 duration and reset at 110% of the level)
- useful for analogical inputLess than (for T1 duration and reset... see more after T2 duration when higher the level)
- useful for numeric inputGreater than (for T1 duration and reset at 90% of the level)
- useful for analogical inputGreater than (for T1 duration and reset after T2 duration when lower the level)
- useful for numeric inputInverse
- time (5points), external resetFrequency meter, with 4 outputs: rate(Hz/s), period(s), deltaF (pu) and F (hz); based on phase C measurementPI with variables low and hi limitsPI with variables Kp and Ki, low and hi limitsLim(du/dt) , rising and falling fixed, Lim(du/dt) , rising and falling variableFour second order filters,
Tag(s): Components
A collection of PowerRelay devices
Description:
A collection of PowerRelay devices
Distance relay 21,
Synchronizing or synchronism-check device 25,
Instantaneous overcurrent 50 + Ac time overcurrent relay 51,
Frequency relay (ov... see moreer) 81O,
Frequency relay (rate) 81R,
Frequency relay (under) 81U
Plus 6 controlled switch build to connect with theses protection devices.
Tag(s): Protection