Exchange Platform

To download or upload a file, please login

page 9 of 22

108 Results for the search "te":

See Tutorial on exported mask (Demonstrated with an exciter)

Author: h.gras
Type: Example
Downloaded: 240 times
Date: 2017-02-03

Rating:
* 1 vote(s)

Tutorial on exported mask (Demonstrated with an exciter)

Description:
In this example, a device is placed in a subcircuit. The goal is to be able to modify the parameters of this device from the parent mask.
However, this device is a masked subcircuit and therefore... see more


Tag(s): exported, mask, exciter, governor, subcircuit, subnetwork, script, method

See Tutorial example on ZnO modelling

Author: h.gras
Type: Example
Downloaded: 724 times
Date: 2016-10-11

Rating:
* 2 vote(s)

Tutorial example on ZnO modelling

Description:
In this example, it is detailed step by step how to built a ZnO surge arrester model following the IEEE working group 3-4-11.
The model is built using different impulse test results.


Tag(s): ZnO, surge, arrester, IEEE, 3-4-11, impulse

See Micro-Grid library

Author: h.gras
Type: Library
Downloaded: 1360 times
Date: 2016-03-16

Rating:
* 7 vote(s)

Micro-Grid library

Description:
Convenient library to study Micro-grid. Contain:
- a 3-phase inverted with dq0 control (PQ, PV, VF, droop)
- a battery model (Ideal, i-Ion, Lead-Acid, NiMH, NiCD)
- a PV park
- Win... see more


Tag(s): Micro, grid, smart, inverter, dq0, battery, BMS, VSC, filter, delay, trigger, Wind, PV, photovoltaic, park, power, electronics

See Fault Current Limiters in Industrial Power Systems

Author: n.sene
Type: Publication
Date: 2015-10-22

Rating:
* 4 vote(s)

Fault Current Limiters in Industrial Power Systems

Description:
The concept of saturable core fault current limiter (FCL) is relatively known nowadays. It usually consists of two reversely magnetized cores per phase to effectively limit the fault current passively... see more


Tag(s): saturable core fault current limiter (FCL), industrial power system, induction machine, EMTP; fault current analysis, medium voltage

See Content of the webinar studies from A to Z on TRV

Author: h.gras
Type: Example
Downloaded: 669 times
Date: 2015-06-16

Rating:
* 3 vote(s)

Content of the webinar studies from A to Z on TRV

Description:
Designs built or presented during the webinar of the series Studies from A to Z on Transient Recovery Voltage
Models built:
- Rating TRV envelop (IEC 62271-100 / C37.010 - 2011)
- CP / ... see more


Tag(s): TRV, Transient recovery voltage, short-line fault, terminal fault, substation, 62271, 37.011, lines, switching, thevenin

Most Downloaded

Top Model Exchanges

Top Examples

X