67 Results for the search "EV":
Author: e.rutovic
Type: Library
Downloaded: 427 times
Date: 2013-02-26
Control Devices of TACS
Description:
An EMTP-RV TACS (Transient Analysis Control Systems Library) containing :
- TACS 50 : Frequency meter
- TACS 51 : Relay
- TACS 52 : Level-Switch
- TACS 53 : Delay
- TACS 54 :... see more Pulse delay
- TACS 55 : Digitizer
- TACS 56 : X-Y point list
- TACS 57 : Sequenced switch
- TACS 58: Integrator
- TACS 59 : Derivator
- TACS 60 : Input Selector
- TACS 61 : Input Selector
- TACS 62 : Sample and Track
- TACS 63 : Instantaneous Max/Min
- TACS 64 : Max tracking
- TACS 65 : Accumulator
- TACS 66 : RMS Meter
Tag(s): TACS
Author: gerinlajoie.luc
Type: Model
Downloaded: 431 times
Date: 2012-11-23
Extra control of machines - IEEE AVR
Description:
The proposed AVR sub-circuit models consist of a few IEEE 421 standard exciter[1] and Power Systems Stabilizer and governor. Don't forget to click the require observed signals in the SM devi... see morece, see Observe and Mechanical Tabs (vd, vq, if, Pmss, Efss, Omega_1, etc.) In this file, many duos and trios combinations of:
Exciter:
- IEEEX1 (dc1),
- IEEEX2,
- IEEEX4,
- IEEET5,
- EXST1,
- EXST1A,
Stabilizer:
- PSS1A,
- PSS2B,
- PSS4B,
- Q type II (var control)
Governor:
- IEEEG0,
- IEEEG1,
- IEEEG3,
- DEGOV1
- GAST,
- TGOV1,
- TGOV5[1]
IEEE Std 421.5, Recommended Practice for Excitation System Models For Power System Stability Studies, 2005
Tag(s): Components
Author: gerinlajoie.luc
Type: Model
Downloaded: 235 times
Date: 2012-11-23
Extra control functions
Description:
Extra control functions, 17 components: Dead band, Friction, QuantizerLess than (for T1 duration and reset at 110% of the level)
- useful for analogical inputLess than (for T1 duration and reset... see more after T2 duration when higher the level)
- useful for numeric inputGreater than (for T1 duration and reset at 90% of the level)
- useful for analogical inputGreater than (for T1 duration and reset after T2 duration when lower the level)
- useful for numeric inputInverse
- time (5points), external resetFrequency meter, with 4 outputs: rate(Hz/s), period(s), deltaF (pu) and F (hz); based on phase C measurementPI with variables low and hi limitsPI with variables Kp and Ki, low and hi limitsLim(du/dt) , rising and falling fixed, Lim(du/dt) , rising and falling variableFour second order filters,
Tag(s): Components
Author: gerinlajoie.luc
Type: Library
Downloaded: 523 times
Date: 2012-11-23
A collection of PowerRelay devices
Description:
A collection of PowerRelay devices
Distance relay 21,
Synchronizing or synchronism-check device 25,
Instantaneous overcurrent 50 + Ac time overcurrent relay 51,
Frequency relay (ov... see moreer) 81O,
Frequency relay (rate) 81R,
Frequency relay (under) 81U
Plus 6 controlled switch build to connect with theses protection devices.
Tag(s): Protection
Author: gerinlajoie.luc
Type: Model
Downloaded: 123 times
Date: 2012-11-23
Pseudo Aleatory Volt/Ampere source
Description:
Pseudo Aleatory Volt/Ampere source single and three phases devices. Build with Base Line Wander generator. Useful for Spectrum Analysis
nota bene: ts must be a multiple of dt.
Tag(s): Source