Technical Presentations

Access to EMTP user presentations, webinars, and slide deck presentations.

page 3 of 10

48 presentations for DER:


Ground Fault Detection and Feeder Protection of 2x25kV Railway Traction System

Author(s): Mr. Suyash Kulkarni - Mr. Suved - M. Pakade
Type:Technical Presentation
Date: 2021-09-03

Rating:
* 0 vote(s)

Ground Fault Detection and Feeder Protection of 2x25kV Railway Traction System


Abstract
In a new 2X25 kV System, Scott transformer is used as a traction transformer and to supply the power to the railway traction system. It is protected using the percentage differential relay.

... see more

Tag(s): Fault Detection, protection, railway, traction

Simulation of Inductive EM Interference Caused by an HVDC Underground Cable Link on a Railway System

Author(s): Theofilos Papadopoulos
Type:Technical Presentation
Date: 2021-09-03

Rating:
* 0 vote(s)

Simulation of Inductive EM Interference Caused by an HVDC Underground Cable Link on a Railway System


Abstract
Scope of the presentation is to present results regarding inductive electromagnetic interference (EMI) between a real HVDC link and the nearby communication cables of a railway system under pole-to-gr... see more

Tag(s): emi, wb cable, hvdc, interference

Optimization of Control Parameters of Grid-Connected PV System in EMTP

Author(s): Bikrant Poudel
Type:Technical Presentation
Date: 2021-09-02

Rating:
* 0 vote(s)

Optimization of Control Parameters of Grid-Connected PV System in EMTP


Abstract
It is observed that the controller gain parameters of the PV model have a significant impact on the PV plant’s response during the fault recovery and the PV plant’s interaction with the rest of th... see more

Tag(s): pv plant, ibr, pso, optimization, scripting, pll, inverter control, inverter based resources, DER

Dynamic Overvoltage Conditions Experienced at a PV Solar Power Plant

Author(s): Chandra Pallem
Type:Technical Presentation
Date: 2021-09-02

Rating:
* 0 vote(s)

Dynamic Overvoltage Conditions Experienced at a PV Solar Power Plant


Abstract
We present the results from an investigation of the cause of dynamic overvoltage conditions experienced at a solar power plant, that resulted from energizing the PV solar plant 34.5 kV collection syst... see more

Tag(s): pv park, tov, diesel generator, temporary overvoltage

Ground Fault Overvoltage with Inverter-Based Distributed Energy Resources

Author(s): Aboutaleb Haddadi
Type:Technical Presentation
Date: 2021-09-02

Rating:
* 0 vote(s)

Ground Fault Overvoltage with Inverter-Based Distributed Energy Resources


Abstract
A Ground Fault Overvoltage (GFO) can occur in situations where an ungrounded transmission line and associated ungrounded transmission equipment is energized from distribution connected Distributed En... see more

Tag(s): gfov, tov, ibr, DER, inverter, islanding, load rejection, inverter based resources

Most Watched Presentations

X